Every Electrician Calculator, in One Place

Free, NEC-compliant calculators for conduit fill, voltage drop, breaker sizing, grounding, and more โ€” plus dedicated sizing guides for specific appliances and equipment.

Core Calculators

Breaker Sizing โ€” Specific Sizing Guides

Electric Range Circuit Breaker & Wire Size

What size breaker does an electric range need? Standard ranges require a 40A or 50A double-pole breaker on a dedicated 240V circuit per NEC.

Open Calculator

Electric Water Heater Breaker & Wire Size

What size breaker does a water heater need? Standard 4500W electric water heaters require a 30A double-pole breaker with 10 AWG copper wire per NEC rules.

Open Calculator

Electric Dryer Breaker & Wire Size

Standard electric dryers require a 30 amp double-pole breaker with 10 AWG copper wire on a 240V circuit. Learn how to size your dryer circuit.

Open Calculator

Standard Breaker Sizes NEC & Fuse Ratings

Standard breaker sizes per NEC 240.6(A). Comprehensive chart of standard circuit breaker amperage ratings from 15A to 6000A for residential & commercial.

Open Calculator

3-Phase Circuit Breaker & Wire Size Calculator

Calculate 3-phase circuit breaker and wire size. Supports 208V, 240V, and 480V three-phase systems for motors, heaters, and continuous commercial loads.

Open Calculator

Hot Tub & Spa Breaker Size (NEC Article 680)

What size breaker does a hot tub need? Most hardwired 240V spas require a 50 amp GFCI breaker with 6 AWG copper wire per NEC Article 680.

Open Calculator

RV Breaker Size: 30 Amp vs 50 Amp Service

What size breaker for an RV outlet? 30A service uses a single-pole 120V breaker with 10 AWG wire; 50A service uses a double-pole breaker with 6 AWG wire.

Open Calculator

Ductless Mini Split Breaker & Wire Size

What size breaker for a mini split AC unit? Sizing depends on the manufacturer's MCA/MOCP nameplate rating per NEC 440, typically 15A to 30A.

Open Calculator

Built-In Electric Wall Oven Breaker & Wire Size

What size breaker for a built-in wall oven? Most single wall ovens need a 20A-30A double-pole 240V breaker; double wall ovens often require 30A-40A.

Open Calculator

Garbage Disposal Breaker & Wire Size

What size breaker for a garbage disposal? Most residential disposals require a dedicated 15A or 20A 120V circuit with 14 or 12 AWG copper wire.

Open Calculator

Submersible Well Pump Breaker & Wire Size

What size breaker for a well pump? Sizing depends on motor horsepower and full-load amps per NEC Article 430, typically 15A to 30A for residential pumps.

Open Calculator

Dishwasher Breaker & Wire Size

What size breaker for a dishwasher? Most residential dishwashers need a dedicated 15A or 20A 120V circuit with GFCI protection per NEC 210.8(D).

Open Calculator