Tesla Wall Connector Circuit Breaker & Wire Size
Free online tool • 2026 NEC Compliant
The Tesla Wall Connector (Generation 3) supports up to 48 amps of continuous charging current at 240V, delivering up to 11.5 kW. As a continuous load per NEC 625.42, it must be sized at 125%: 48A ร 1.25 = 60A. This requires a 60-amp double-pole breaker and minimum 6 AWG copper wire. Check your panel capacity below.
Existing Loads in Your Panel
Check all loads currently connected to this panel.
Add any known existing circuit amps not listed above.
Panel Capacity Assessment
PANEL CAN SUPPORTRecommended EV Circuit
Breaker Size
40A
240V double-pole
Min Wire Size
8 AWG Cu
75ยฐC rating
Charger Output
32A
continuous load
Panel can support this EV charger. Install a 40A double-pole breaker with 8 AWG Cu wire. Per NEC 625.42, EV chargers must be treated as continuous loads (sized at 125%).
NEC References: NEC 625.42 (EV as continuous load), NEC 625.40 (branch circuit requirements), NEC 220.83 (Optional Residential Load Calculation). This is an estimate โ a licensed electrician should perform a complete load calculation before installation.
How to Use This Calculator
Select 200A or your panel size
Enter your main service panel amperage rating.
Select Level 2 โ 48A charger
This matches the Tesla Wall Connector Gen 3 maximum.
Add existing loads
Check all major appliances in your home.
Review panel capacity
Confirm your panel has headroom for the 60A EV circuit.
Frequently Asked Questions
What breaker size does a Tesla Wall Connector need?
Tesla Wall Connector Gen 3 supports up to 48A, which requires a 60A double-pole 240V breaker (48A ร 125% = 60A per NEC 625.42) and minimum 6 AWG copper wire.
Can I use a 50A breaker for a Tesla Wall Connector?
A 50A breaker limits the Wall Connector to a maximum of 40A output (50A ร 80% = 40A). This is a valid configuration delivering about 9.6 kW of charging power, but you won't get the full 48A (11.5 kW) capability. You need a 60A breaker for maximum speed.
Specific Sizing Guides & Calculators
Related Calculators
Conduit Fill Calculator
Calculate NEC-compliant conduit fill percentages.
Voltage Drop Calculator
Determine voltage drop across wire runs.
Breaker Size Calculator
Find the correct breaker size for your circuit.
Wire Gauge Chart
Reference AWG diameters, ampacities, and limits.
Box Fill Calculator
Verify NEC 314.16 junction box fill compliance.
Grounding Calculator
Size EGC and GEC conductors per NEC Article 250.
Conduit Bending Calculator
Calculate offset, saddle, and stub-up bend marks.
EV Charger Calculator
Size Level 2 EV charger circuits per NEC 625.42.