Electric Water Heater Breaker & Wire Size

Free online tool • 2026 NEC Compliant

Electric water heaters are continuous loads under NEC Article 422. A standard 4,500-watt, 240V residential water heater draws 18.75 amps and, sized at 125% for continuous loads, requires a 30 amp double-pole breaker with 10 AWG copper wire. Use the calculator below to verify sizing for your specific water heater.

Recommended Sizing

NEC Standard Size
25 Amp

Breaker Type: Standard Inverse-Time

Minimum Wire Size (Copper)10 AWG
Wire Ampacity (75ยฐC Rating)35A
Conduit Size (Rough Guide)3/4"
Calculated Load (Amps)25.0A

NEC Reference Note: 125% multiplier applied for continuous loads per NEC 210.20(A).

How to Use This Calculator

Find wattage

Check the water heater nameplate for element wattage (typically 4500W).

Calculate draw

Watts รท 240V = amps (4500 รท 240 = 18.75A).

Apply 125% continuous factor

18.75A ร— 1.25 = 23.4A minimum breaker.

Select standard size

Round up to 30A from NEC 240.6(A) standard sizes.

Frequently Asked Questions

What size breaker does a water heater need?

A standard 4,500W 240V electric water heater requires a 30 amp double-pole circuit breaker with 10 AWG copper wire. This is sized at 125% of the 18.75A draw because water heaters are continuous loads per NEC 422.13.

What wire size for a 40 gallon water heater?

Most 40 and 50-gallon residential electric water heaters have a 4,500W heating element at 240V, drawing 18.75A. The required wire is 10 AWG copper on a 30A double-pole breaker.

Can I use a 20 amp breaker for a water heater?

No. A standard 4,500W water heater draws nearly 19 amps, which exceeds the 80% continuous load limit of a 20A breaker. A 30A breaker is required.

Specific Sizing Guides & Calculators

What size breaker does an electric range need? Standard ranges require a 40A or 50A double-pole breaker on a dedicated 240V circuit per NEC.

Standard electric dryers require a 30 amp double-pole breaker with 10 AWG copper wire on a 240V circuit. Learn how to size your dryer circuit.

Standard breaker sizes per NEC 240.6(A). Comprehensive chart of standard circuit breaker amperage ratings from 15A to 6000A for residential & commercial.

Calculate 3-phase circuit breaker and wire size. Supports 208V, 240V, and 480V three-phase systems for motors, heaters, and continuous commercial loads.

What size breaker does a hot tub need? Most hardwired 240V spas require a 50 amp GFCI breaker with 6 AWG copper wire per NEC Article 680.

What size breaker for an RV outlet? 30A service uses a single-pole 120V breaker with 10 AWG wire; 50A service uses a double-pole breaker with 6 AWG wire.

What size breaker for a mini split AC unit? Sizing depends on the manufacturer's MCA/MOCP nameplate rating per NEC 440, typically 15A to 30A.

What size breaker for a built-in wall oven? Most single wall ovens need a 20A-30A double-pole 240V breaker; double wall ovens often require 30A-40A.

What size breaker for a garbage disposal? Most residential disposals require a dedicated 15A or 20A 120V circuit with 14 or 12 AWG copper wire.

What size breaker for a well pump? Sizing depends on motor horsepower and full-load amps per NEC Article 430, typically 15A to 30A for residential pumps.

What size breaker for a dishwasher? Most residential dishwashers need a dedicated 15A or 20A 120V circuit with GFCI protection per NEC 210.8(D).

Related Calculators